The American Psychiatric Association (APA) has updated its Privacy Policy and Terms of Use, including with new information specifically addressed to individuals in the European Economic Area. As described in the Privacy Policy and Terms of Use, this website utilizes cookies, including for the purpose of offering an optimal online experience and services tailored to your preferences.

Please read the entire Privacy Policy and Terms of Use. By closing this message, browsing this website, continuing the navigation, or otherwise continuing to use the APA's websites, you confirm that you understand and accept the terms of the Privacy Policy and Terms of Use, including the utilization of cookies.

×
Regular ArticlesFull Access

Improved Outcomes Using Brain SPECT-Guided Treatment Versus Treatment-as-Usual in Community Psychiatric Outpatients: A Retrospective Case-Control Study

Abstract

Brain single-photon emission computed tomography (SPECT) scans indirectly show functional activity via measurement of regional cerebral blood flow. Thirty patients at a community-based psychiatric clinic underwent brain SPECT scans. Changes in scoring of before-treatment and after-treatment scans correlated well with changes in patient Global Assessment of Functioning (GAF) scores before treatment and after treatment. Patients were retrospectively matched with controls with similar diagnoses and pretreatment GAF scores, and those who underwent SPECT-guided treatment improved significantly more than the control patients.

Single-photon emission computed tomography (SPECT) is a well-established nuclear medical imaging technology thought to show functional activity indirectly via measurement of relative perfusion. Visualizing the different levels of activity in the brain may allow more accurate evaluation of psychiatric disorders by revealing abnormally functioning neural regions and circuits, hence allowing more targeted, effective treatment.15 For example, the finding of increased regional cerebral blood flow (rCBF) in the subgenual cingulate and prefrontal cortex demonstrated by SPECT predicted which depressed patients would more readily respond to citalopram.4

In recent years, the analysis and visual representation of SPECT, which we term “3D SPECT,” has been shown to facilitate the management of psychiatric patients.1,3,6 3D SPECT processes the scanning data via thresholding functions to synthesize a 3D model of the brain. (See Figure 1 and Figure 2.) Pixels representing the top 45% of activity are used in creating the outside cortical 3D surface view of the brain, and the top 8%, 15%, and 45% pixels create the three-dimensional view of the interior of the patient’s brain. These thresholds reflect the early work of I. Mena and colleagues79 and have been used by Amen6 in tens of thousands of SPECT scans. The term “3D SPECT” herein refers to the production of such SPECT images.

FIGURE 1. Example of a Brain 3D SPECT ECD Image, Outside Cortical 3D Inferior Surface View

Perfusion defects representing hypoperfusion bilaterally in the prefrontal cortex are seen, as well as bilateral defects in the antero-medial aspects of the temporal lobes.

ECD: ethyl cysteinate dimer.

FIGURE 2. Interior View of Brain Shown in Figure 1 (3D SPECT ECD Image)

Top 8%, 15%, and 45% pixels are represented respectively by white, red, and blue colors. The activity seen in this view in the occipital region and elsewhere is largely within normal limits.

The literature shows that for particular disorders, the defects on SPECT scans correlate with the clinical deficits. For example, Ichise and colleagues10 have shown, in traumatic brain injury, a correlation between brain SPECT defects and neuropsychological performance. However, in a full-spectrum, community-based psychiatric practice, does an objective scoring of before-treatment and after-treatment SPECT scans correlate with an objective measure of patient functioning before and after treatment? Another question to be answered is a clinically important one: Is 3D brain SPECT scanning a useful procedure for the community clinician? Do patients who receive SPECT scans and SPECT-guided treatment improve more in final functioning than matched-control patients who receive treatment-as-usual that does not involve SPECT scans?

Methods

Brain SPECT scans were offered to patients at a community-based psychiatric clinic. Patients at this clinic had problems with anxiety and depression, as well as frequently subtle cognitive dysfunction as a consequence of injury or chronic pain, which had not responded successfully to primary-care intervention. No attempt to select patients was made. As scanning slots were made available at the local hospital, they were offered to patients in the clinic. Only a few patients each month could be scanned. Thirty patients, without regard to diagnosis, age, severity, or other factors, were offered SPECT scans in the context of routine clinical care. As part of the clinical evaluation, Global Assessment of Functioning (GAF) scores were obtained before and after treatment, as per the guidelines of the American Psychiatric Association DSM-IV-TR.11

The SPECT scanning was performed according to the guidelines established by the Society of Nuclear Medicine.12 Patients received an intravenous injection of the 99m-technetium-labeled brain perfusion agent ethyl cysteinate dimer (ECD; 15–20 mCi) in a sitting position in a quiet, dimly-lit room. The uptake of ECD in the brain is complete in less than 90 seconds. Technetium-99m is a metastable nuclear isomer of technetium-99 with a half-life of 6.01 hours. The use of 99mTc-labeled brain perfusion agents has been well established over the last two decades.13,14 Approximately ½ to 1 hour after injection (so as to allow clearance of 99m-Tc-ECD from non-neural tissues during this time) the patient’s head was scanned with a Picker Prism 3000 three-headed camera; collimation: fan beams; matrices: 128 × 128; acquisition: 120 frames over 360 degrees; attenuation correction: calculated Chang first-order attenuation correction; processing: iterative, ordered subsets expectation maximization (OSEM) reconstruction; masking: image voxels outside the head/brain region were set to 0 by applying a mask to the reconstructed transaxial images; post-filtering: a 3D low-pass post-filter was applied to reduce noise; 3D SPECT scans generated via Picker Prism Odyssey Rendering Software: outside (cortical) views: top 45% limits; interior views: top 8%, 15%, 45% limits.

The information provided by the SPECT scan, in combination with the patient’s clinical data, was used to decide upon the course of treatment or changes to an existing course of treatment. Treatment was predominantly psychopharmacological, but all patients received supportive psychotherapy and psychoeducation. The psychopharmacological modifications were guided by the functional abnormalities suggested by the brain SPECT scans. For example, if the anterior cingulate gyrus was over-perfused, then an SSRI could be added; or, for example, if a defect (under-perfusion) in an anterior temporal lobe was observed, then an anticonvulsant could be added. In a number of cases, the prefrontal cortex was hypoperfused, whereby a stimulant or a stimulating-antidepressant could be added as part of management. A summary of some frequently-observed findings on 3D SPECT brain scans and possible treatment strategies is presented in Table 1.36,15,16

TABLE 1. Relationship Between 3D SPECT Findings and Their Clinical Significance
SPECT FindingAssociated Clinical Significance and Possible Treatments36,15,16
“Defect”Reduced regional cerebral perfusion with various clinical symptoms resulting
Defect in orbitofrontal prefrontal cortexAssociated with ADHD-like symptoms
Possible treatment: stimulants or stimulating-antidepressants
Defect in temporal lobeAssociated with mood instability, irritability
Possible treatment: anticonvulsants
Anterior cingulate gyrus hyperperfusionAssociated with obsessive-compulsive symptoms, unwillingness to change ideas/behavior
Possible treatments: CBT, SSRIs
Thalamic hyperperfusionAssociated with depression and negativity
Possible treatments: CBT, antidepressants
If focal increased activity or clinically cyclic: lithium, anticonvulsants
Basal ganglia hyperperfusionAssociated with anxiety
Possible treatments: relaxation techniques, antidepressants, anticonvulsants
Patchy hyperperfusion pattern throughout brain, focal increased uptake in the thalamusAssociated with hypomanic/manic-like symptoms
Possible treatments: treatments for bipolar disorder
Scalloping of cerebral surfaceAssociated with drug/alcohol/toxin/benzodiazepine exposure/use
Symptoms depend on local severity
Localized defects with history of brain traumaSymptoms depend on localization and extent of defects

ADHD: attention-deficit hyperactivity disorder; CBT: cognitive-behavior therapy; SSRIs: selective serotonin-reuptake inhibitors.

TABLE 1. Relationship Between 3D SPECT Findings and Their Clinical Significance
Enlarge table

After stabilization (mean time: 17 months) of patients on the new treatment regime, a second brain 3D SPECT scan was completed. As mentioned above, GAF scores were obtained at the start of treatment and also after the second SPECT scan. Of the 30 patients, 2 patients did not want psychopharmacological treatment, leaving 28 patients who continued with scheduled treatment.

Twenty-eight control patients from the same community-based psychiatric clinic were retrospectively matched to the 28 patients who received SPECT scans and who completed scheduled treatment. Matching was done on the basis of initial GAF scores and diagnosis, and then, where possible, by sex and age. Control patients had not received any SPECT scans. Controls had received psychopharmacological treatment, as well as psychotherapy and psychoeducation. In Table 2, the scanned patients are compared with the control patients.

TABLE 2. Characteristics of SPECT-Scanned Patients and Control Patients
Patients Undergoing SPECT Scans, Completed TreatmentMatched-Control Patients From Same Community-Based Practice
N2828
Mean age, years5152
Women, %7171
Patients matched to opposite sex, %00
Mood disorders, %4350
Anxiety disorders, %1814
Psychosomatic disorders, %3936
Mean initial GAF score46.049.9
Mean final GAF score59.858.5
Mean increase in GAF score13.88.6

SPECT: single-photon emission computed tomography; GAF: Global Assessment of Functioning.

TABLE 2. Characteristics of SPECT-Scanned Patients and Control Patients
Enlarge table

SPECT Scan Image and Clinical Data Analysis

A quantitatively-based visual scoring system17 for the 3D SPECT brain images was developed, and scans were scored by three community-based psychiatric practitioners without knowledge of patient clinical information. As some discussion occurred about the scans between these readers, scores were simply averaged, and interrater reliability was not computed. The clinician who provided care to the patients did not rate any of the 3D SPECT scans.

Since patients had heterogeneous findings on their scans (e.g., some with decreased perfusion in temporal lobes, some with decreased perfusion in prefrontal cortex, and so on), the visual scoring system17 obtained a SPECT improvement score for each pair of before-and-after SPECT scans. The SPECT score was computed by giving 5 points for any major increase in areas with initially abnormally low perfusion (or major decreases in areas of initially abnormally elevated perfusion). For minor increases (or decreases) in perfusion relative to the initial scan, 1 or 2 points were assigned in each region. In the instance of markedly-increased perfusion, compared with an initial scan with globally decreased perfusion, a value of 10 points was assigned. The normal scans used as references were the age-adjusted normal 3D SPECT scan images provided by Amen.6 Also used as an adjunct reference for normal scans was the work of Tanaka and colleagues,14 which assessed patterns on 99m-Tc-ECD brain scans of “normal” adults (no psychiatric or neurological history), albeit 2D scans, and without regard to the areas of increased perfusion.

In the analysis of the results, if an improvement of ≥10 points occurred, then this was arbitrarily considered to be a positive improvement in the SPECT scan. If there was an improvement of <10 points, then this was considered to be no significant improvement (i.e., a negative result). Since the first part of this data analysis is to simply see whether there is a correlation between the SPECT scan score and the patient’s functioning (as shown by the GAF score changes below), and not the more clinically important question of whether SPECT scans result in better outcomes for patients, we decided against constructing a receiver operator characteristic (ROC) curve18 and forcing a positive correlation by this or other preemptive statistical methods. The SPECT scan ratings would not influence patient outcome; they were simply there to see whether a basic correlation existed with patients’ functioning.

Half of a GAF scoring range (i.e., half of 10 points, or 5 points) was arbitrarily taken to indicate significant improvement in functioning. If the after-treatment GAF score exceeded the pretreatment GAF score by ≥5 points, then this was considered to be a positive GAF improvement. If there was less than a 5-point increase in GAF scores, then this was considered to be a negative GAF improvement. The relationship between patients’ clinical GAF scores and their SPECT scan scores was then analyzed by chi-square test.

With regard to the next objective of whether patients who underwent SPECT scans improved more in their functioning than matched case controls, as mentioned above, 28 control patients from the same community-based psychiatric clinic were retrospectively matched to the 28 patients who received SPECT scans and who completed scheduled treatment. Changes in GAF score (i.e., final GAF score – initial GAF score) of the patients receiving SPECT scans were compared with the changes in GAF scores of the matched controls. Paired t-test statistics were applied to these sets of GAF score changes.

Results

GAF improvement × SPECT improvement of the 30 patients who underwent pre-treatment and post-treatment SPECT scans are shown in the chi-square model presented in Table 3.

TABLE 3. SPECT Improvement by GAF Improvement
Positive SPECT ImprovementNegative SPECT Improvement
Positive GAF improvement, N23 patients3 patients
Negative GAF improvement, N0 patients4 patients
TABLE 3. SPECT Improvement by GAF Improvement
Enlarge table

The calculated chi-square value is 10.6, which allows rejection of the null hypothesis of no association of SPECT score changes with GAF score changes at a statistically significant value of p <0.01. Thus, an objective scoring of before-and-after treatment SPECT scans correlates with an objective scoring of patients’ functioning before and after treatment as shown by this chi-square analysis.

It is interesting to note, but not of statistical significance, that in this heterogeneous mix of community psychiatric patients, all 3 patients who showed a positive GAF score improvement but a negative SPECT improvement had been diagnosed with fibromyalgia. Work by Usui and colleagues19 of performing ECD SPECT scans on 29 patients and 10 controls, similarly showed a wide variety of perfusion abnormalities in fibromyalgia patients.

Paired t-test statistics were then applied to the change in GAF scores of patients who underwent SPECT scans compared with the change in GAF scores of matched controls who did not undergo SPECT scans. The group of patients who received SPECT scans showed on average an increase of 13.8 in their final GAF scores, versus the matched-control patients, who showed on average an increase of 8.6 in their final GAF scores. The t value was 2.4, and the two-tailed p value equaled 0.023 (p <0.05). Thus, at the 5% significance level, patients who underwent SPECT scans improved more in their clinical functioning than matched case controls.

Discussion

Our retrospective analysis showed that before- and after-treatment SPECT scans correlated in a statistically significant manner with before- and after-treatment levels of patients’ functioning (GAF scores). On the important clinical level, our retrospective analysis showed that community patients who underwent 3D brain SPECT scans and SPECT-guided treatment improved more in functioning than their matched controls who did not undergo SPECT scans and SPECT-guided treatment. This latter analysis did not use any arbitrary scoring system other than the well-established GAF scores, and, in a very straightforward manner, compared outcome as indicated by GAF score improvement, of patients who had SPECT scans versus their matched controls who did not have any scans. Work by Amen and colleagues20 has shown that the addition of brain SPECT modified the diagnosis or treatment in 79% of 109 consecutive psychiatric outpatients. In our study, the ability of SPECT scans to modify diagnosis or treatment of psychiatric outpatients was further extended to outcome.

Other reasons for the improvement in patients’ functioning should be considered. For the patient, there is the potential placebo effect of undergoing the actual brain SPECT scan, as well as the perceived psychological benefit of feeling that one is getting more attention from the clinician. Similarly, it is possible that the clinician felt more empowered to try different or more aggressive treatments in patients who received scans than in other patients in the practice.

SPECT is a well-established nuclear medical imaging technology. 3D SPECT combines the scanning data via thresholding functions to synthesize a 3D model of the brain. This retrospective study showed that 3D brain SPECT scanning improved community psychiatric patient outcome.

From Rossiter-Thornton Associates, Toronto, Ontario, Canada; Sheppard Associates, Toronto, Ontario, Canada (HS); Dept. of Nuclear Medicine and Division of Adult Psychiatry, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.
Send correspondence to Dr. Schneider, Sheppard Associates; e-mail:

The authors thank Dr. Lisa Ehrlich for her assistance in making this study possible.

This work was approved by Canadian SHIELD Ethics Review Board #12-08-001.

No conflicts of interest disclosed by any author.

References

1 Amen DG, Carmichael BD: High-resolution brain SPECT imaging in ADHD. Ann Clin Psychiatry 1997; 9:81–86Crossref, MedlineGoogle Scholar

2 Sheehan W, Thurber S: Review of two years of experiences with SPECT among psychiatric patients in a rural hospital setting. J Psychiatr Pract 2008; 14:318–323Crossref, MedlineGoogle Scholar

3 Amen DG, Hanks C, Prunella J: Preliminary evidence differentiating ADHD using brain SPECT imaging in older patients. J Psychoactive Drugs 2008; 40:139–146Crossref, MedlineGoogle Scholar

4 Brockmann H, Zobel A, Joe A, et al.: The value of HMPAO SPECT in predicting treatment response to citalopram in patients with major depression. Psychiatry Res 2009; 173:107–112Crossref, MedlineGoogle Scholar

5 Kanahara N, Shimizu E, Sekine Y, et al.: Does hypofrontality expand to global brain area in progression of schizophrenia? a cross-sectional study between first-episode and chronic schizophrenia. Prog Neuropsychopharmacol Biol Psychiatry 2009; 33:410–415Crossref, MedlineGoogle Scholar

6 Amen DG: Images of Human Behavior: A Brain SPECT Atlas. Newport Beach, CA, Mindworks Press, 2004Google Scholar

7 Mena FJ, Mena I, Alamos BA, et al.: SPECT Tc99m-HMPAO brain uptake in normal children: a comparison to normal elderly subjects. Alasbimn Journal 1998; 1:AJ01-3; http://www.alasbimnjournal.cl/revistas/1/children.htmGoogle Scholar

8 Darcourt J, Mena I, Cauvin J-C, et al.: Absolute calibration of HMPAO SPECT, using 133-Xe rCBF values. Alasbimn Journal 1999; 2:http://www.alasbimnjournal.cl/revistas/5/darcourt.htmGoogle Scholar

9 Payne JK, Trivedi MH, Devous MD: Comparison of technetium-99m-HMPAO and xenon-133 measurements of regional cerebral blood flow by SPECT. J Nucl Med 1996; 37:1735–1740MedlineGoogle Scholar

10 Ichise M, Chung DG, Wang P, et al.: Technetium-99m-HMPAO SPECT, CT and MRI in the evaluation of patients with chronic traumatic brain injury: a correlation with neuropsychological performance. J Nucl Med 1994; 35:217–226MedlineGoogle Scholar

11 American Psychiatric Association: Diagnostic and Statistical Manual of Mental Disorders, 4th Edition (DSM-IV-TR). Washington, DC, American Psychiatric Publishing, Inc., 2000Google Scholar

12 Juni JE, Waxman AD, Devous MD, et al.: Procedure Guideline for Brain Perfusion SPECT Using 99mTc Radiopharmaceuticals, 3.0. July 2009, Society of Nuclear Medicine; http:// www.snm.org/guidelinesGoogle Scholar

13 Leveille J, Demonceau G, Walovitch RC: Intrasubject comparison between technetium-99m-ECD and technetium-99m-HMPAO in healthy human subjects. J Nucl Med 1992; 33:480–484Google Scholar

14 Tanaka F, Vines D, Tsuchida T, et al. Normal patterns on 99m-Tc-ECD brain SPECT scans in adults. J Nuclear Med 2000; 41:1456–1464Google Scholar

15 Gowda NK, Agrawal D, Bal C, et al.: Technetium Tc-99m ethyl cysteinate dimer brain single-photon emission CT in mild traumatic brain injury: a prospective study. Am J Neuroradiol 2006; 27:447–451MedlineGoogle Scholar

16 Cherkasova MV, Hechtman L: Neuroimaging in attention-deficit hyperactivity disorder: beyond the frontostriatal circuitry. Can J Psychiatry 2009; 54:651–664Crossref, MedlineGoogle Scholar

17 Thornton J, Schneider H: A quantitatively-based visual scoring system for 3D SPECT brain images, 2009; available at Google Scholar

18 Hanley JA, McNeil BJ: A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 1983; 148:839–843Crossref, MedlineGoogle Scholar

19 Usui C, Hatta K, Doi N, et al.: Brain perfusion in fibromyalgia patients and its differences between responders and poor responders to gabapentin. Arthritis Res Ther 2010; vol. 12CrossrefGoogle Scholar

20 Amen DG, Highum D, Licata R, et al.: Specific ways brain SPECT imaging enhances clinical psychiatric practice. J Psychoactive Drugs 2012; 44:96–106Crossref, MedlineGoogle Scholar